jueves, 16 de junio de 2016

Single-Reaction Multiplex Reverse Transcription PCR for Detection of Zika, Chikungunya, and Dengue Viruses - Volume 22, Number 7—July 2016 - Emerging Infectious Disease journal - CDC

Single-Reaction Multiplex Reverse Transcription PCR for Detection of Zika, Chikungunya, and Dengue Viruses - Volume 22, Number 7—July 2016 - Emerging Infectious Disease journal - CDC



Volume 22, Number 7—July 2016

Dispatch

Single-Reaction Multiplex Reverse Transcription PCR for Detection of Zika, Chikungunya, and Dengue Viruses

Jesse J. Waggoner, Lionel Gresh, Alisha Mohamed-Hadley, Gabriela Ballesteros, Maria Jose Vargas Davila, Yolanda Tellez, Malaya K. Sahoo, Angel Balmaseda, Eva Harris, and Benjamin A. PinskyComments to Author 
Author affiliations: Stanford University School of Medicine, Stanford, California, USA (J.J. Waggoner, A. Mohamed-Hadley, M.K. Sahoo, B.A. Pinsky)Sustainable Sciences Institute, Managua, Nicaragua (L. Gresh);Laboratory Centro Nacional de Diagnóstico y Referencia of the Ministry of Health, Managua (G. Ballesteros, M.J. Vargas Davila, Y. Tellez, A. Balmaseda)School of Public Health of the University of California, Berkeley, Berkeley, California, USA (E. Harris)

Abstract

Clinical manifestations of Zika virus, chikungunya virus, and dengue virus infections can be similar. To improve virus detection, streamline molecular workflow, and decrease test costs, we developed and evaluated a multiplex real-time reverse transcription PCR for these viruses.
Zika virus is a mosquitoborne flavivirus that, in 2015, spread throughout the tropical and subtropical regions of the Western Hemisphere. In January 2016, the first autochthonous cases of Zika fever were confirmed in Nicaragua (1). The diagnosis of human Zika virus infections is confounded by a nonspecific clinical presentation, which overlaps substantially with that of dengue virus (DENV) and chikungunya virus (CHIKV) (2,3) and by cross-reaction with DENV IgM and DENV nonstructural protein 1 in assays for Zika virus (47).
Molecular assays can detect and differentiate these 3 pathogens during the acute phase of illness. Although a number of molecular tests have been published for detecting DENV and CHIKV, only 2 Zika virus real-time reverse transcription PCRs (rRT-PCRs) have been reported and were characterized by using human specimens (68). These assays are run as individual reactions, and molecular testing for all 3 viruses, using established protocols, requires multiple reactions for a single patient sample (6,9,10). We describe a Zika virus rRT-PCR that was designed to be run in multiplex with published assays for pan-DENV and CHIKV detection (11,12). We then evaluated the single-reaction multiplex rRT-PCR for Zika virus, CHIKV, and DENV (referred to as the ZCD assay) by testing clinical samples from persons with suspected cases in Nicaragua.

The Study

The Zika virus primers and probe (Technical Appendix[PDF - 191 KB - 4 pages]Table 1) were designed by using all complete or nearly complete (>10,000 kb) Zika virus genome sequences available in GenBank (n = 21) accessed March 28, 2014). Target sequences were subsequently confirmed to match strains from the Americas. All rRT-PCR reactions were performed on an ABI 7500 instrument (Applied Biosystems, Foster City, CA, USA) by using 25-μL reactions of the SuperScript III Platinum One-Step qRT-PCR kit (Life Technologies, Carlsbad, CA, USA) and 5 μL of RNA template. Cycling conditions for the ZCD assay were as follows: 52°C for 15 min; 94°C for 2 min; 45 cycles at 94°C for 15 sec, 55°C for 20 sec (acquisition), and 68°C for 20 sec. Each run included a no-template control and positive controls for Zika virus, CHIKV, and DENV.
Linear range and lower limit of 95% detection (95% LLOD) for each target were determined as recommended. We determined linear range and 95% LLOD for each target as recommended (13Technical Appendix[PDF - 191 KB - 4 pages]). The linear range of the ZCD assay extended from 108 to 10 copies/μL for Zika virus and DENV-3 and from 108 to 100 copies/μL for DENV-1, −2, −4, and CHIKV. The 95% LLOD for each target, in copies/μL of eluate (5 μL added to each ZCD reaction), was as follows: Zika virus, 7.8; CHIKV, 13.2; DENV-1, 11.7; DENV-2, 13.5; DENV-3, 4.1; DENV-4, 10.5.
Assay exclusivity was established by testing genomic RNA from the following viruses: West Nile, Japanese encephalitis, tickborne encephalitis, yellow fever, Saint Louis encephalitis, o’nyong-nyong, Semliki Forest, Mayaro, Ross River, Getah, Barmah Fores, and Unas (12,14). No amplification was detected for any of these viruses.
De-identified serum samples, collected from Nicaraguan patients with suspected Zika virus, CHIKV, and/or DENV infections, were tested (Technical Appendix[PDF - 191 KB - 4 pages]). We tested 216 samples by using the ZCD assay and the pan–DENV-CHIKV rRT-PCR, which is a validated duplex assay containing the DENV and CHIKV primers and probes used in the ZCD assay (12). Both assays were performed on an ABI7500 (Applied Biosystems) (Table 1). A total of 173 samples were positive for DENV alone (n = 25), CHIKV alone (n = 110), or both (n = 38). The ZCD assay and pan–DENV-CHIKV rRT-PCR showed very good agreement for DENV detection (κ = 0.907). Six of 8 discrepant samples were co-infected with DENV and CHIKV, and the 2 discrepant samples with DENV mono-infections had cycle threshold (Ct) values of 41.34 and 42.25. The 2 assays demonstrated good agreement for CHIKV detection (κ = 0.662). Ct for the 35 CHIKV discrepant samples were reached significantly later (mean 39.8, SD ±1.5) than the 113 concordant samples (28.7, ±SD 9.7; p<0.0001).
The first case of Zika virus infection in Nicaragua was detected with the ZCD assay during the assay comparison described above. After Zika virus identification, 133 consecutive samples were tested by using both the ZCD assay and a comparator Zika virus rRT-PCR targeting the capsid gene (6) (Table 2). When the comparator rRT-PCR was analyzed according to the published validation (Ct <38.5 defining a positive result), these assays demonstrated only moderate agreement (κ = 0.47), and Zika virus was detected in significantly more samples by using the ZCD assay (p<0.001). Of the 31 samples positive only for Zika virus in the ZCD assay, 22 (71%) produced a Ct (>38.5) that was reached later in the comparator Zika virus rRT-PCR. These 22 samples had mean Ct of 32.06 (SD ±2.45) in the ZCD assay and 42.09 (SD ±1.41) in the comparator Zika virus rRT-PCR. If all samples in the comparator rRT-PCR with Ct>38.5 were considered positive, the assays demonstrated very good agreement (κ = 0.81; Technical Appendix[PDF - 191 KB - 4 pages] Table 2). Of the 56 Zika virus–positive samples in the ZCD assay, 39 were positive only for Zika virus, and 17 showed evidence of mixed infection: Zika virus–DENV (n = 3); Zika virus–CHIKV (n = 10 ), or Zika virus–CHIKV–DENV (n = 4).

Conclusions

The ZCD assay improved detection of Zika virus relative to the comparator rRT-PCR, and 31 samples were positive only for Zika virus by the ZCD assay when the comparator was interpreted as published (6). Notably, 22 (71%) of these 31 samples produced a late signal in the comparator Zika virus rRT-PCR (Ct >38.5), indicating that these most likely are true, late-positive results. Improved sensitivity for Zika virus is needed given the low viremia detected in clinical samples and the current lack of accurate alternative diagnostics, such as serology (6,7,15). Additionally, the ZCD assay identified 17 co-infections in Zika virus–positive patients. Although preliminary, these data provide evidence for the utility of a multiplex diagnostic test for these pathogens.
The performance of the ZCD assay for DENV detection was similar to that of the pan–DENV-CHIKV rRT-PCR, and the analytical sensitivity for CHIKV was similar in both assays (12). CHIKV detection in clinical samples in the ZCD assay and pan–DENV-CHIKV rRT-PCR demonstrated good agreement, although both assays contain the same CHIKV primers and probes. Discrepant samples all had Ct of >37.36, which correspond to 10 copies/μL of eluate and fall below the 95% LLOD. Although ZCD assay results for these CHIKV-positive samples were reproducible, the clinical significance of such low-level viremia in patients with suspected chikungunya fever is unclear and warrants further study.
A limitation to our study is the use of a single comparator Zika virus rRT-PCR. This assay was 1 of 2 rRT-PCRs developed for the 2007 Yap Island Zika virus strain (6). The second rRT-PCR, targeting the membrane gene, was evaluated for the current study but proved consistently less analytically sensitive. Therefore, performance of this second Zika virus assay most likely would not have affected result interpretation.
In conclusion, the single-reaction multiplex ZCD assay detected and differentiated Zika virus, CHIKV, and DENV. This assay should streamline molecular workflow and decrease test costs while improving detection of these 3 human arboviruses.
Dr. Waggoner is an instructor in the Division of Infectious Diseases and Geographic Medicine at the Stanford University School of Medicine, Stanford, California. His research intrests include implementation and evaluation of improved diagnostics for pathogens important to the global health community

Acknowledgments

We thank Lark L. Coffey for providing genomic RNA from reference alphavirus isolates. We thank the staff of the Stanford Clinical Virology Laboratory, and we are grateful to past and present members of the study team based at the Centro de Salud Sócrates Flores Vivas, the National Virology Laboratory in the Centro Nacional de Diagnóstico y Referencia of the Nicaraguan Ministry of Health, and the Sustainable Sciences Institute in Managua, Nicaragua.
Patent applications or provisional patent applications that cover the ZCD multiplex assay and the primers and probes described in this report have been filed (J.J.W. and B.A.P.).
This research was supported by National Institute of Allergy and Infectious Diseases of the National Institutes of Health (NIH) grant K08AI110528 (to J.J.W.) and the Robert E. Shope International Fellowship in Infectious Diseases from the American Society of Tropical Medicine and Hygiene. Studies in Nicaragua were supported by NIH grants R01AI099631 (to A.B.) and U54AI65359 (to A.B.), NIH contract HHSN2722001000026C (to E.H. and A.B.), and VE-1 (to E.H.) from the Pediatric Dengue Vaccine Initiative. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.

References

  1. El Nuevo Diario. Confirman dos casos positivos de Zika en Nicaragua [cited 2016 Apr 13]. http://www.elnuevodiario.com.ni/nacionales/383401-nicaragua-confirma-dos-casos-positivos-zika/
  2. Duffy MRChen THHancock WTPowers AMKool JLLanciotti RSZika virus outbreak on Yap Island, Federated States of Micronesia. N Engl J Med2009;360:253643DOIPubMed
  3. Zanluca CMelo VCMosimann ALSantos GISantos CNLuz KFirst report of autochthonous transmission of Zika virus in Brazil. Mem Inst Oswaldo Cruz2015;110:56972DOIPubMed
  4. Fonseca KMeatherall BZarra DDrebot MMacDonald JPabbaraju KFirst case of Zika virus infection in a returning Canadian traveler. Am J Trop Med Hyg2014;91:10358DOIPubMed
  5. Gyurech DSchilling JSchmidt-Chanasit JCassinotti PKaeppeli FDobec MFalse positive dengue NS1 antigen test in a traveller with an acute Zika virus infection imported into Switzerland. Swiss Med Wkly2016;146:w14296 .PubMed
  6. Lanciotti RSKosoy OLLaven JJVelez JOLambert AJJohnson AJGenetic and serologic properties of Zika virus associated with an epidemic, Yap State, Micronesia, 2007. Emerg Infect Dis2008;14:12329DOIPubMed
  7. Waggoner JJPinsky BA. Zika virus: diagnostics for an emerging pandemic threat. J Clin Microbiol. 2016;54:860–7.;54:860–7.
  8. Faye OFaye ODupressoir AWeidmann MNdiaye MAlpha Sall AOne-step RT-PCR for detection of Zika virus. J Clin Virol2008;43:96101.DOIPubMed
  9. Lanciotti RSKosoy OLLaven JJPanella AJVelez JOLambert AJChikungunya virus in US travelers returning from India, 2006. Emerg Infect Dis.2007;13:7647DOIPubMed
  10. Lanciotti RSCalisher CHGubler DJChang GJVorndam AVRapid detection and typing of dengue viruses from clinical samples by using reverse transcriptase–polymerase chain reaction. J Clin Microbiol1992;30:54551 .PubMed
  11. Waggoner JJAbeynayake JSahoo MKGresh LTellez YGonzalez KDevelopment of an internally controlled real-time reverse transcriptase PCR assay for pan-dengue virus detection and comparison of four molecular dengue virus detection assays. J Clin Microbiol2013;51:217281DOIPubMed
  12. Waggoner JJBallesteros GGresh LMohamed-Hadley ATellez YSahoo MKClinical evaluation of a single-reaction real-time RT-PCR for pan-dengue and chikungunya virus detection. J Clin Virol2016;78:5761DOIPubMed
  13. Burd EMValidation of laboratory-developed molecular assays for infectious diseases. Clin Microbiol Rev2010;23:55076DOIPubMed
  14. Waggoner JJAbeynayake JSahoo MKGresh LTellez YGonzalez KSingle-reaction, multiplex, real-time RT-PCR for the detection, quantitation, and serotyping of dengue viruses. PLoS Negl Trop Dis2013;7:e2116DOIPubMed
  15. Musso DRoche CNhan TXRobin ETeissier ACao-Lormeau VMDetection of Zika virus in saliva. J Clin Virol2015;68:535 . DOIPubMed

Tables

Technical Appendix

Suggested citation for this article: Waggoner JJ, Gresh L, Mohamed-Hadley A, Ballesteros G, Vargas Davila MJ, Tellez Y, et al. Single-reaction multiplex PCR for detection of Zika, chikungunya, and dengue viruses. Emerg Infect Dis. 2016 Jul [date cited]. http://dx.doi.org/10.3201/eid2207.160326


DOI: 10.3201/eid2207.160326

No hay comentarios:

Publicar un comentario