martes, 21 de mayo de 2019

National Surveillance of Legionnaires’ Disease, China, 2014–2016 - Volume 25, Number 6—June 2019 - Emerging Infectious Diseases journal - CDC

National Surveillance of Legionnaires’ Disease, China, 2014–2016 - Volume 25, Number 6—June 2019 - Emerging Infectious Diseases journal - CDC

Issue Cover for Volume 25, Number 6—June 2019



Volume 25, Number 6—June 2019
Research Letter

National Surveillance of Legionnaires’ Disease, China, 2014–2016

Tian QinComments to Author , Hongyu Ren, Dongke Chen, Haijian Zhou, Luxi Jiang, Duorong Wu, Jilu Shen, and Fengyan Pei
Author affiliations: Chinese Center for Disease Control and Prevention, Beijing, China (T. Qin, H. Ren, H. Zhou, L. Jiang)State Key Laboratory for Infectious Disease Prevention and Control, Beijing (T. Qin, H. Zhou)Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, Hangzhou, China (T. Qin, H. Zhou)Beijing Hospital, Beijing (D. Chen)Haikou People's Hospital, Haikou, China (D. Wu)The Fourth Affiliate Hospital of Anhui Medical University, Hefei, China (J. Shen)Jinan Central Hospital, Jinan, China (F. Pei)

Abstract

We report national surveillance of Legionnaires’ disease in China. Urine samples from 11 (3.85%) of 286 patients with severe pneumonia of unknown cause were positive for the Legionella pneumophilaserogroup 1 antigen. We isolated Legionella strains from 7 patients. Improved diagnostic testing is needed for this underestimated disease in China.
Legionnaires’ disease is a form of atypical pneumonia caused by bacteria of the genus LegionellaL. pneumophila serogroup 1 causes most Legionnaires’ disease (1). Although Legionnaires’ disease has been reported worldwide, only a few sporadic cases have been reported in China (2). Investigation of Legionellainfection is urgently needed in China to describe its prevalence and epidemiology.
During 2014–2016, we conducted surveillance of Legionnaires’ disease in 18 hospitals in China under the coordination of the Chinese Center for Disease Control and Prevention (China CDC). The Ethical Committee of the National Institute for Communicable Disease Control and Prevention, China CDC (ICDC-2014009), provided ethics approval for this study. The distribution of the 18 hospitals accounted for all regions of China (Appendix Figure 1). The hospital's clinical diagnostic level, pneumonia pathogen detection level, and degree of cooperation with this investigation were also considered. All 18 hospitals are level 3 first-class general hospitals, representing the highest level of healthcare in their cities.
The 3,132 severe pneumonia cases were defined and detected according to the Guidelines for the Diagnosis and Treatment of Community-Acquired Pneumonia in Adults in China (2016 edition) (3) (Appendix Figure 2). Among them, 1,885 cases were diagnosed as noninfectious or nonbacterial infections, and 771 cases were diagnosed as bacterial infections other than Legionella by daily testing, including bacterial culture, viral nucleic acid detection, and immunologic detection in hospital laboratories. Patients with the remaining 476 cases of pneumonia with unknown cause were enrolled and tested for Legionella infection. Among them, 190 left the hospital, died, or were unwilling to cooperate. Thus, urine samples were collected from 286 patients and sent for urine antigen detection for L. pneumophila serogroup 1 (BinaxNow, https://www.alere.comExternal Link) (Appendix Figure 2). Sputum samples were obtained from 211 of the 286 patients and sent to the laboratory of China CDC (Beijing, China) for Legionella culture, which used both buffered charcoal yeast extract agar and buffered charcoal yeast extract agar supplemented with Legionella GVPC (glycine, vancomycin, polymyxin, cycloheximide) Selective Supplement (Oxoid, https://www.thermofisher.comExternal Link). Eleven (3.85%) of the 286 urine samples yielded positive results, and we isolated Legionella strains from 7 of them. All 7 L. pneumophila cultures were obtained from the same patients who tested positive by urine antigen detection. The positive rate of Legionella culture was 3.32% (7/211). All isolated Legionella strains were L. pneumophila serogroup 1.
All 11 urine antigen–positive patients were male, 23–76 years of age (average 56 years) (Table). They resided in 7 cities, and most (9/11) cases were observed in summer (in China, July–September). All were hospitalized; length of hospitalization ranged from 7 to 93 days. Six were admitted to an intensive care unit. The case-fatality rate was 18.2% (2/11) after antimicrobial and supportive therapies.
We performed antimicrobial susceptibility testing using E-test strips (bioMérieux, https://www.biomerieux.comExternal Link). According to the epidemiologic cutoff values of the European Committee on Antimicrobial Susceptibility Testing (4) or as determined by a previous study (5), all 7 strains were susceptible to fluoroquinolones, macrolides, and rifampin but not to cefuroxime (Appendix Table 1).
We subtyped the 7 strains using pulsed-field gel electrophoresis (6) and sequence-based typing (SBT) (7). All 7 strains were identified as different pulsed-field gel electrophoresis and SBT types (Appendix Figure 3). Submission to the European Working Group on LegionellaInfections L. pneumophila SBT database (http://www.ewgli.orgExternal Link) identified 4 profiles as new; these profiles were assigned new sequence types (STs) (ST2344, ST2366, ST2368, and ST2369). Querying the European Working Group on Legionella Infections database showed that 2 STs (ST42 and ST59) contained strains that are distributed worldwide (Appendix Table 2). We also tested the 7 strains for their intracellular growth ability using previously described methods (8), and all showed high intracellular growth in J774 cells, suggesting that these strains are pathogenic (Appendix Figure 4).
Many Legionnaires’ disease cases are reported worldwide, including hundreds in the United States and Europe each year (9,10). However, no data are available on the prevalence of Legionnaires’ disease in China. In China, no Legionella urine antigen test reagent has been approved for clinical diagnosis and few hospitals conduct Legionella culture, so in clinical laboratories, Legionnaires’ disease is difficult to detect; therefore, diagnosis is based mainly on signs and symptoms. Legionnaires’ disease is usually diagnosed as unexplained pneumonia.
The results of this study showed that L. pneumophila is an important pathogen for pneumonia patients in China, and current diagnostic methods in China may misdiagnose or overlook it. We suggest establishment of a routine monitoring reporting system to investigate the prevalence and epidemiology of Legionnaires’ disease in China.
Dr. Qin is a microbiologist at the National Institute for Communicable Disease Control and Prevention, Chinese CDC, Beijing. Her research interests are surveillance of Legionnaires’ disease, and the molecular subtyping and genomic diversity of Legionella.

Acknowledgment

This study was supported by grants from the National Natural Science Foundation of China (grant no. 81671985) and the Science Foundation for the State Key Laboratory for Infectious Disease Prevention and Control from China (grant no. 2015SKLID508).

References

  1. Diederen  BMWLegionella spp. and Legionnaires’ disease. J Infect2008;56:112DOIExternal LinkPubMedExternal Link
  2. Zhang  QZhou  HChen  RQin  TRen  HLiu  Bet al. Legionnaires’ disease caused by Legionella pneumophila serogroups 5 and 10, China. Emerg Infect Dis2014;20:12423DOIExternal LinkPubMedExternal Link
  3. Chinese Society of Respiratory Diseases, Chinese Medical AssociationGuidelines for the diagnosis and treatment of community-acquired pneumonia in adults in China (2016 edition). Zhonghua Jie He He Hu Xi Za Zhi2016;39:25379.
  4. The European Committee on Antimicrobial Susceptibility Testing. Antimicrobial susceptibility testing of Legionella pneumophila. [cited 2016 Sep 9]. http://www.eucast.org/fileadmin/src/media/PDFs/EUCAST_files/General_documents/Legionella_guidance_document_20160909.pdfExternal Link
  5. Bruin  JPIjzerman  EPden Boer  JWMouton  JWDiederen  BMWild-type MIC distribution and epidemiological cut-off values in clinical Legionella pneumophila serogroup 1 isolates. Diagn Microbiol Infect Dis2012;72:1038DOIExternal LinkPubMedExternal Link
  6. Zhou  HRen  HZhu  BKan  BXu  JShao  ZOptimization of pulsed-field gel electrophoresis for Legionella pneumophila subtyping.Appl Environ Microbiol2010;76:133440DOIExternal LinkPubMedExternal Link
  7. Ratzow  SGaia  VHelbig  JHFry  NKLück  PCAddition of neuA, the gene encoding N-acylneuraminate cytidylyl transferase, increases the discriminatory ability of the consensus sequence-based scheme for typing Legionella pneumophila serogroup 1 strains. J Clin Microbiol2007;45:19658DOIExternal LinkPubMedExternal Link
  8. Qin  TZhang  WLiu  WZhou  HRen  HShao  Zet al.Centers for Disease Control and Prevention (CDC)Legionellosis --- United States, 2000-2009. MMWR Morb Mortal Wkly Rep2011;60:10836.PubMedExternal Link
  9. Joseph  CARicketts  KDon behalf of the European Working G  CEuropean Working Group for Legionella InfectionsLegionnaires disease in Europe 2007-2008. Euro Surveill2010;15:19493DOIExternal LinkPubMedExternal Link
Table
Cite This Article

DOI: 10.3201/eid2506.171431
Original Publication Date: 4/23/2019