sábado, 19 de octubre de 2019

Fatal Case of Nosocomial Legionella pneumophila Pneumonia, Spain, 2018 - Volume 25, Number 11—November 2019 - Emerging Infectious Diseases journal - CDC

Fatal Case of Nosocomial Legionella pneumophila Pneumonia, Spain, 2018 - Volume 25, Number 11—November 2019 - Emerging Infectious Diseases journal - CDC



Issue Cover for Volume 25, Number 11—November 2019

Volume 25, Number 11—November 2019
Dispatch

Fatal Case of Nosocomial Legionella pneumophila Pneumonia, Spain, 2018

Diego VicenteComments to Author , Jose M. Marimón, Itziar Lanzeta, Tania Martin, and Gustavo Cilla
Author affiliations: Universidad del País Vasco, País Vasco, Spain (D. Vicente)Hospital Donostia-Instituto Biodonostia, San Sebastian, Spain (D. Vicente, J.M. Marimón, I. Lanzeta, T. Martin)Centro de Investigación Biomédica en Red Enfermedades Respiratorias, Madrid, Spain (D. Vicente, J.M. Marimón, G. Cilla)

Abstract

A nosocomial case of Legionella pneumophila pneumonia likely caused by a serogroup 3 strain was detected by a urinary antigen test in Spain in 2018. Although Legionella bacteria could not be isolated from respiratory samples, molecular methods implicated the sink faucet of the patient’s room as the probable infection source.
Legionnaires’ disease (LD) is a severe form of pneumonia caused primarily by the inhalation of Legionella spp. bacteria from colonized natural and artificial water systems. The annual incidence of LD in developed countries is ≈1 case/100,000 inhabitants and has been increasing in recent years (1,2). This increase is attributed in part to the widespread use of the urinary antigen test (UAT) as a diagnostic method. UAT is a fast and simple method, with good sensitivity and specificity to confirm the clinical suspicion of LD; however, most commercial tests only detect Legionella pneumophila serogroup 1. In many countries, UAT is used as the only LD diagnostic method. This strategy leads to the loss of detection of episodes caused by non–serogroup 1 L. pneumophila, including L. pneumophila serogroups 2–14, and other Legionella species (1,2).
We describe an episode of nosocomial L. pneumophila pneumonia probably caused by a serogroup 3 strain, which was diagnosed by UAT and genomic detection of Legionella DNA in respiratory samples. The episode was linked to the detection of the causative agent in the water of the sink of the patient’s room.

The Study

In February 2018, a 66-year-old man sought care at Hospital Donostia-Instituto Biodonostia (San Sebastian, Spain) because of progressive loss of strength, accompanied by dysarthria and altered state of consciousness. A cranial computed tomography scan performed at hospital admission showed a deep intraparenchymal hematoma and a substantial surrounding edema. After a 1-month hospitalization in the neurology department, the patient was transferred to the long-stay unit of the internal medicine department, where he occupied the same room until the end of the episode. During this period, he was treated with high doses of dexamethasone to reduce the cerebral edema and different cycles of antibiotics (piperacillin/tazobactam and ceftriaxone) because of the presence of abundant respiratory secretions.
In April 2018, the patient had acute worsening of respiratory function, requiring high oxygen flow rates and mechanical ventilation. A chest radiograph showed the appearance of bilateral pulmonary infiltrates, and we observed elevated sepsis-associated markers in the blood analysis.
The patient was given a presumptive diagnosis of nosocomial pneumonia. We obtained a urine sample, 2 blood cultures, and 2 respiratory samples (sputum and tracheal aspirate) for microbiologic analysis. Blood cultures were negative. Results of a fluorescent immunoassay (Sofia Legionella FIA, https://www.quidel.comExternal Link) detected L. pneumophila antigen in the urine, a result that was confirmed in a second sample obtained 12 hours later. Both urine samples had a negative result when tested with the Alere BinaxNOW Legionella Antigen Test Kit (Fisher Scientific, https://www.fishersci.comExternal Link), which only detects L. pneumophila serogroup 1 (3). In the microbiologic culture of respiratory samples, we observed a scanty growth of saprophytic bacteria, but a culture on selective media Legionella (BCYE agar) was negative. The multiplex PCR for detection of Legionella spp., Chlamydia pneumoniae, and Mycoplasma pneumoniae (BioGX, https://biogx.comExternal Link) performed on the BD MAX System (https://www.bd.comExternal Link) was positive for Legionella spp., both in the sputum and in the tracheal aspirate. The patient received levofloxacin but died 48 hours later.
After establishing the diagnosis of LD, we conducted an investigation to determine the origin of the episode and monitored the appearance of more cases. No episodes of Legionella spp. pneumonia were detected among patients admitted to the same unit during the previous month and during the month after the episode. We obtained samples of water from 23 different points of the internal medicine department unit where the patient had stayed, including his room’s sink faucet and shower as well as another 5 rooms, an office, spillways, and refrigeration equipment.
Non–serogroup 1 L. pneumophila (i.e., serotyped 2–14 in our microbiology department) was isolated in glycine, vancomycin, polymyxin, cycloheximide agar plates from the sink faucet of the patient’s room (1,250 cfu/L) and from the sink faucet (275 cfu/L) and shower faucet (1,250 cfu/L) of the contiguous room. Disinfection of the affected facilities through thermal shock was performed, and the disappearance of Legionella was verified by using the same methods described. Monoclonal antibody subgrouping conducted at Spain’s National Center for Microbiology identified Legionella isolates from these 3 environmental samples as serogroup 3. No more L. pneumophila was detected in any of the other 20 water samples we analyzed.
We performed sequence-based typing on DNA extracted from the sputum and the tracheal aspirate of the patient and from the 3 environmental isolates. We sequenced and amplified fragments of 7 genes in accordance a with protocol established by the European Working Group for Legionella Infections (EWGLI) (4), which includes the use of specific primers for the neuA homologue allele neuAh (5). We applied a nested PCR–derived sequence based typing method directly to DNA extracted from respiratory samples (6) and assigned allele and sequence type by using the online EWGLI SBT Database (7). The Legionella spp. detected in the 2 respiratory samples of the patient, as well as in the water of the patient’s and a contiguous room, were identified as sequence type 1341.

Conclusions

Most LD episodes reported worldwide are attributed to L. pneumophila serogroup 1. Nevertheless, several studies suggest that episodes caused by L. pneumophila other than serogroup 1 might be underestimated because the main current method used for microbiologic diagnosis of LD is the UAT, which in most commercial test kits is limited to the detection of L. pneumophila serogroup 1 (810). The analysis of isolates from patients with Legionella pneumonia, both in Europe and the United States, shows that up to 20% were caused by L. pneumophila serogroups 2–14 or Legionella other than L. pneumophila (1,2,11), and this rate is higher among hospital-associated cases (12). However, Legionella culture is rarely used as a routine diagnostic method (1,2) because of the low efficiency and difficulties in isolation even if the bacterial DNA is present in the sample, as in the case we have described.
In our study, antigen detection in urine was performed by using a method able to detect, in addition to L. pneumophila serogroup 1, lipopolysaccharide of most L. pneumophila serogroups, including serogroup 3, although with a higher limit of detection (3). In addition, a nucleic acid amplification technique that enables detection of all Legionella species was used in respiratory samples, and secondarily, helped indicate an epidemiologic link with the infectious source without microbiologic culture of the causative strain. Although strains of L. pneumophila with identical sequence type can be of different serogroups, our results strongly suggest that the L. pneumophila serogroup 3 ST1341 strain isolated from the water in the sink faucet of the patient’s room was the source of the nosocomial pneumonia episode. The L. pneumophila serogroup 3 ST1341, probably responsible for the nosocomial pneumonia episode we describe, was also reported in the EWGLI SBT Database in 3 LD episodes (2 in Germany and 1 in Catalonia, Spain) (7) and in an environmental sample in Greece (8). The strain does not seem to be a frequent genotype, although the case we have described supports the potential of nearly all Legionella genotypes to cause fatal infection.
Even though L. pneumophila serogroup 1 is responsible for most LD episodes, it is advisable to have techniques to detect other serogroups and species of Legionella, especially in the hospital environment, where the presence of non–serogroup 1 L. pneumophila is frequent (8,12) and a high number of susceptible immunosuppressed patients are present.
Dr. Vicente is a medical microbiologist at the Hospital Donostia–Instituto Biodonostia, San Sebastian, Spain. His research focuses on respiratory infections and antimicrobial resistance.

Acknowledgments

This study was supported by grants from the Centro de Investigación Biomédica en Red Enfermedades Respiratorias (grant no. CIBERES CB06/06/0056), an initiative of the Instituto de Salud Carlos III (Madrid, Spain).
Diego Vicente received speaker’s fees from Werfen, the distributor of Quidel’s Sofia Legionella FIA in Spain, for participation in the Agora Meeting (an annual scientific meeting for microbiologists sponsored by Werfen) held in Madrid on September 29, 2016.

References

  1. Beauté  JThe European Legionnaires’ Disease Surveillance NetworkLegionnaires’ disease in Europe, 2011 to 2015. Euro Surveill2017;22:22DOIExternal LinkPubMedExternal Link
  2. Dooling  KLToews  KAHicks  LAGarrison  LEBachaus  BZansky  Set al. Active Bacterial Core Surveillance for Legionellosis - United States, 2011-2013. MMWR Morb Mortal Wkly Rep2015;64:11903DOIExternal LinkPubMedExternal Link
  3. Ranc  AGCarpentier  MBeraud  LDescours  GGinevra  CMaisonneuve  Eet al. Legionella pneumophila LPS to evaluate urinary antigen tests. Diagn Microbiol Infect Dis2017;89:8991DOIExternal LinkPubMedExternal Link
  4. Mentasti  MFry  NK. European Society of Clinical Microbiology and Infectious Diseases Study Group for Legionella Infections. Sequence-based typing protocol for epidemiological typing of Legionella pneumophila2012 [cited 2019 Sep 11]. http://www.hpa-bioinformatics.org.uk/legionella/legionella_sbt/php/protocols/ESGLI%20SBT%20GUIDELINE%20v5.0.pdfExternal Link
  5. Mentasti  MUnderwood  ALück  CKozak-Muiznieks  NAHarrison  TGFry  NKExtension of the Legionella pneumophila sequence-based typing scheme to include strains carrying a variant of the N-acylneuraminate cytidylyltransferase gene. Clin Microbiol Infect2014;20:O43541DOIExternal LinkPubMedExternal Link
  6. Ginevra  CLopez  MForey  FReyrolle  MMeugnier  HVandenesch  Fet al. Evaluation of a nested-PCR-derived sequence-based typing method applied directly to respiratory samples from patients with Legionnaires’ disease. J Clin Microbiol2009;47:9817DOIExternal LinkPubMedExternal Link
  7. European Working Group for Legionella Infections. EWGLI Sequence-Based Typing (SBT) Database for Legionella pneumophila [cited 2019 Sep 11]. http://www.hpa-bioinformatics.org.uk/legionella/legionella_sbt/php/sbt_homepage.phpExternal Link
  8. Katsiaflaka  APournaras  SKristo  IMouchtouri  VAKyritsi  MVelonakis  Eet al. Epidemiological investigation of Legionella pneumophila serogroup 2 to 14 isolates from water samples by amplified fragment length polymorphism and sequence-based typing and detection of virulence traits. Appl Environ Microbiol2016;82:61028DOIExternal LinkPubMedExternal Link
  9. European Centre for Disease Prevention and Control. Legionnaires disease in Europe, 2014. 2016 [cited 2019 Sep 11]. https://ecdc.europa.eu/sites/portal/files/media/en/publications/Publications/legionnares-disease-europe-2014.pdfExternal Link
  10. Benson  RFTang  PWFields  BSEvaluation of the Binax and Biotest urinary antigen kits for detection of Legionnaires’ disease due to multiple serogroups and species of Legionella. J Clin Microbiol2000;38:27635.External Link
  11. Quero  SPárraga-Niño  NBarrabeig  ISala  MRPedro-Botet  MLMonsó  Eet al. Population structure of Environmental and Clinical Legionella pneumophila isolates in Catalonia. Sci Rep2018;8:6241DOIExternal LinkPubMedExternal Link
  12. Lévesque  SLalancette  CBernard  KPacheco  ALDion  RLongtin  Jet al. Molecular typing of Legionella pneumophila isolates in the province of Quebec from 2005 to 2015. PLoS One2016;11:e0163818DOIExternal LinkPubMedExternal Link
Cite This Article

DOI: 10.3201/eid2511.181069
Original Publication Date: 9/26/2019

No hay comentarios:

Publicar un comentario