lunes, 7 de octubre de 2019

A recurrent and transesophageal echocardiography–associated outbreak of extended-spectrum β-lactamase–producing Enterobacter cloacae complex in cardiac surgery patients | Antimicrobial Resistance & Infection Control | Full Text

A recurrent and transesophageal echocardiography–associated outbreak of extended-spectrum β-lactamase–producing Enterobacter cloacae complex in cardiac surgery patients | Antimicrobial Resistance & Infection Control | Full Text



Antimicrobial Resistance & Infection Control

A recurrent and transesophageal echocardiography–associated outbreak of extended-spectrum β-lactamase–producing Enterobacter cloacae complex in cardiac surgery patients

Article metrics

Abstract

Background

We report a recurrent outbreak of postoperative infections with extended-spectrum β-lactamase (ESBL)–producing E. cloacae complex in cardiac surgery patients, describe the outbreak investigation and highlight the infection control measures.

Methods

Cases were defined as cardiac surgery patients in Ghent University Hospital who were not known preoperatively to carry ESBL-producing E. cloacae complex and who postoperatively had a positive culture for this multiresistant organism between May 2017 and January 2018. An epidemiological investigation, including a case-control study, and environmental investigation were conducted to identify the source of the outbreak. Clonal relatedness of ESBL-producing E. cloacae complex isolates collected from case patients was assessed using whole-genome sequencing–based studies.

Results

Three separate outbreak episodes occurred over the course of 9 months. A total of 8, 4 and 6 patients met the case definition, respectively. All but one patients developed a clinical infection with ESBL-producing E. cloacae complex, most typically postoperative pneumonia. Overall mortality was 22% (4/18). Environmental cultures were negative, but epidemiological investigation pointed to transesophageal echocardiography (TEE) as the outbreak source. Of note, four TEE probes showed a similar pattern of damage, which very likely impeded adequate disinfection. The first and second outbreak episode were caused by the same clone, whereas a different strain was responsible for the third episode.

Conclusions

Health professionals caring for cardiac surgery patients and infection control specialists should be aware of TEE as possible infection source. Caution must be exercised to prevent and detect damage of TEE probes.

No hay comentarios:

Publicar un comentario