Pseudomonas poae–Associated Fatal Septic Transfusion Reaction, Peoria, Illinois, USA, 2017

Therese S. Woodring and John J. FarrellComments to Author 
Author affiliations: University of Illinois College of Medicine, Peoria, Illinois, USA (T.S. Woodring, J.J. Farrell)OSF System Laboratory, Peoria (J.J. Farrell)

Abstract

In the United States, fatal transfusion-transmitted infections from red blood cell units are rare. Although this pattern mostly reflects how inhospitable refrigerated red blood cell units are to contaminant growth, fatalities caused by microorganisms that can grow at storage temperature (4°C), but not in standard clinical blood cultures at 37°C, are probably underestimated. We analyzed a fatal red blood cell transfusion in Peoria, Illinois, USA, that occurred in 2017. Samples from the patient’s whole blood and the red blood cell unit remained culture-negative during the investigation, despite direct visualization of gram-negative bacilli within the unit immediately after transfusion. We identified the bacteria as Pseudomonas poae, a nonpathogenic pseudomonad carrying multiple cold-shock domain protein genes, and confirmed its cold tolerance and inability to grow at 37°C. Our work indicates transfusion reaction workups need to include testing for psychrophilic organisms, which could explain the cause of other apparently culture-negative transfusion reactions.
Transfusion-transmitted infections (TTIs; i.e., the transmission of bacteria, viruses, parasites, or prions through blood product transfusions) are reportable events (1). Although >5 million patients in the United States receive red blood cell transfusions each year, fatal TTIs from contaminated red blood cell units number in the single digits annually and arise primarily from Babesia infection in the donor (Table 1). Bacterial colonization of the red blood cell unit is a much rarer event, and viruses and prions, which are the target of most donor history questionnaires and blood product screening tests, have not contributed to reported fatalities in the past decade. The rarity of bacterial contamination reflects vigilant collection practices for all blood products, including skin disinfection and diversion of the first few milliliters of blood from healthy donors, as well as red blood cell refrigeration, which further decreases contamination risk compared with nonrefrigerated blood products, like platelets.
Still, the rate of fatalities resulting from red blood cell contamination, particularly by bacteria, is surprisingly low, given that, unlike platelets, bacterial contamination of red blood cell units is not screened for after collection, apart from a serologic test for syphilis and visual inspection for gross contamination immediately before transfusion (4). Moreover, pathogen inactivation technologies used after collection for plasma and platelets are not yet available for red blood cells (5). This low rate of bacterial contamination might partly reflect how inhospitable the red blood cell unit becomes to contaminating organisms over its 42-day shelf life. Held at only a few degrees above freezing (4°C), the unit becomes progressively depleted of high-energy substrates, and waste products and reactive oxygen species accumulate at a pH well below the physiologic pH range for blood (6,7). Bacteria that can grow to life-threatening numbers in this environment must be capable of surviving these conditions, and the risk for contamination with these organisms within collection facilities is rare enough to pose minimal threat to the blood supply.
Organisms adapted for survival in packed red blood cell units during storage, however, could be missed during evaluations of suspected transfusion reactions in the clinical laboratory by virtue of their specialized growth limitations. For instance, bacteria best suited to survive in a refrigerated red blood cell unit might not grow at 37°C, the standard temperature for incubation of suspected TTI workups. Yet, these bacteria do not need to grow at this temperature to trigger a fatal septic reaction upon infusion if their inoculum size is large and endotoxin concentration high. The Centers for Disease Control and Prevention National Healthcare Safety Network guidelines for definite TTIs require evidence of the infectious agent in the transfused unit or recipient (Table 2) (8). When standard laboratory testing is used alone, these cases involving cold-tolerant bacteria could be excluded from fatality statistics for TTIs. We present a case report of a death occurring after transfusion with a contaminated red blood cell unit; the investigation required advanced techniques, such as whole-genome sequencing (WGS), to determine the colonizing agent.

Clinical Case

Thumbnail of Timeline of patient’s hospitalization for periprosthetic joint infection, followed by fatal septic transfusion reaction, Peoria, Illinois, USA, 2017. Hb, hemoglobin; MRSA, methicillin-resistant Staphylococcus aureus; PEA, pulseless electrical activity; RBC, red blood cell.
Figure 1. Timeline of patient’s hospitalization for periprosthetic joint infection, followed by fatal septic transfusion reaction, Peoria, Illinois, USA, 2017. Hb, hemoglobin; MRSA, methicillin-resistant Staphylococcus aureus; PEA, pulseless electrical activity; RBC, red blood...
In 2017, a 56-year-old woman with a history of diabetes mellitus, hypertension, and right femur fracture requiring open reduction and internal fixation with total knee arthroplasty (TKA) was admitted to a hospital in Peoria, Illinois, USA, with leg pain and inability to walk. Her TKA had been complicated 5 months earlier by periprosthetic femur fracture and infection with Corynebacterium striatum and Pseudomonas aeruginosa, which was treated with intravenous vancomycin and cefepime. At admission, she was noted to have purulent drainage from an open right thigh wound above a long plate in her femur (Figure 1), and blood and wound cultures were positive for methicillin-resistant Staphylococcus aureus. She was immediately started on intravenous vancomycin, and operative incision and drainage were performed on day 4 of hospitalization without complications. By the day the TKA prosthetic was scheduled for removal (day 6), her blood cultures were negative for bacterial growth.
On day 6, medical staff attempted explant of the TKA hardware; however, the procedure needed to be aborted because of excessive blood loss during debridement. Her preoperative hemoglobin concentration dropped from 10.3 g/dL to 5.5 g/dL within 1 hour of the procedure. She received 3 units of typed and crossed packed red blood cells without complication. Five hours after this transfusion, her hemoglobin rose to 8.4 g/dL, but a repeat hemoglobin assessment 21 hours later indicated the concentration dropped (7.0 g/dL), so another red blood cell unit was ordered for her.
Within 5 minutes of starting the final transfusion, the patient became tachypneic; tachycardia developed, and she began to report shortness of breath. According to hospital protocol, the transfusion was stopped immediately. Clerical error and a hemolytic transfusion reaction were excluded by repeat donor ABO typing, a direct antiglobulin test, and visual inspection of plasma and urine for hemolysis. The red blood cell unit had no signs of hemolysis or breached bag integrity. Despite empiric treatment for an allergic transfusion reaction, the patient continued to exhibit signs of a systemic inflammatory response (heart rate 120–140 beats/min, respiratory rate 35–40 breaths/min) and required increasing oxygen supplementation from a nonrebreather mask and bilevel positive pressure ventilation. Three hours after the transfusion, the laboratory reported gram-negative bacteria throughout smears taken from the red blood cell unit as part of laboratory protocol for suspected transfusion reactions. The patient was started on intravenous piperacillin/tazobactam but continued to deteriorate, undergoing 4 episodes of cardiopulmonary resuscitation before she was declared dead of cardiac arrest 10 hours after the transfusion. Standard 37°C clinical blood cultures from both the patient and the red blood cell unit were negative for bacterial growth after 5 days. The transfusion reaction was reported to the Food and Drug Administration 6 days after the patient’s death.

Methods

For blood culture testing, we inoculated a BACTEC Peds Plus (BD, https://www.bd.comExternal Link) blood culture bottle with 1.0 mL of blood from the red blood cell unit and left the sample at ambient temperature (25°C) for 24 h. Using this culture, we streaked organisms onto a blood agar purity plate and incubated for 24 h at 25°C. We spotted 1 purified colony for matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (VITEK MS; bioMérieux, https://www.biomerieux-diagnostics.comExternal Link) and suspended another colony from the same plate in sterile saline of 0.99 McFarland turbidity standard in preparation for WGS. We extracted DNA from the suspended colony using the QIAGEN REPLI-g UltraFast Mini Kit (https://www.qiagen.comExternal Link) according to manufacturer instructions and sequenced with a FLO-MIN 106 SpotON Flow Cell on a Nanopore MinION Mk1B (Oxford Nanopore Technologies, https://nanoporetech.comExternal Link) using a rapid whole-genome amplification protocol (SQK-RAD004).
We analyzed reads passing the default quality score cutoff of 7 for quality in NanoPlot (9) and assembled de novo using Canu version 1.7.1, an assembler designed for long-read output (10). We evaluated the assessment of the de novo assembly quality using Bandage (11). We retained contigs with >5× coverage for further error correction using Nanopolish 0.8.5 with default settings (12) and annotated the final assembly with Prokka 1.13.3 (13). We identified the species by analyzing the 16S rRNA sequence using the Ribosomal Database Project Seqmatch tool and blastn (https://blast.ncbi.nlm.nih.gov/Blast.cgiExternal Link) within the National Center for Biotechnology Information database. We performed multilocus sequence analysis with 4 conserved gene regions previously used for Pseudomonas taxonomy (16S-gyrB-rpoB-rpoD) on the isolate assembly and 20 fluorescens subgroup genomes available in GenBank (Table 3) (14). For multilocus sequence analysis, we aligned each gene region with MUSCLE before concatenation in Geneious 11.1.5 (15).
After WGS analysis, we analyzed temperature-dependent viability by incubating isolates from the original blood agar purity plate in BD BACTEC Peds Plus blood culture bottles at 4°C, 25°C, and 37°C for 5 days. We plated cultures diluted 1:100–1:10,000,000 on blood agar and counted the colonies that grew after 24 h at 25°C.

Laboratory Investigation

Initial isolate identification by MALDI-TOF mass spectrometry was split between Pseudomonas fluorescens (50% confidence) and Pveronii(50% confidence). WGS produced a total of 168,870 reads spanning 885,192,362 bp that passed the quality threshold. The median read length was 3,200 (maximum 100,184) bp. The assembly contained 2 contigs: a 7,340,165-bp contig with 23.4× coverage corresponding to the predicted chromosomal length of Pseudomonas spp. (GenBank accession no. CP034537) and a 150,410-bp contig with 41.6× coverage suggestive of a plasmid (GenBank accession no. CP034538).
Thumbnail of Neighbor-joining tree calculated by using Jukes-Cantor model for concatenated 16S-gyrB-rpoB-rpoD gene sequences of the Pseudomonas isolate from patient in Peoria, Illinois, USA, 2017 (bold), and 20 fluorescens subgroup pseudomonads. We used P. aeruginosa as the outlier. Scale bar indicates nucleotide substitutions per site.
Figure 2. Neighbor-joining tree calculated by using Jukes-Cantor model for concatenated 16S-gyrB-rpoB-rpoDgene sequences of the Pseudomonasisolate from patient in Peoria, Illinois, USA, 2017 (bold), and 20 fluorescens subgroup pseudomonads. We used...
Among the 8,602 genes annotated on the chromosome were 6 full-length 16S rRNA genes, consistent with the higher 16S gene copy numbers seen in the Pfluorescens and Pputida clusters (n = 5–7) compared with the copy number of P. aeruginosa clusters (n = 4) (16). The sequence of this gene matched with >99% similarity to that of P. poae, a fluorescens group pseudomonad, by both the Ribosomal Database Project Seqmatch tool and blastn (Table 4). In multilocus sequence analysis (16S-gryrB-rpoB-rpoD), the isolate also clustered with Ppoae, further supporting this identification (Figure 2).
Thumbnail of Titers of viable bacteria in cultures of Pseudomonas poae from patient in Peoria, Illinois, USA, 2017. Cultures were grown in BD BACTEC Peds Plus (https://www.bd.com) blood culture media incubated at 4°C, 25°C, and 37°C for 5 days.
Figure 3. Titers of viable bacteria in cultures of Pseudomonas poae from patient in Peoria, Illinois, USA, 2017. Cultures were grown in BD BACTEC Peds Plus (https://www.bd.comExternal Link) blood culture media incubated at...
Thumbnail of Pseudomonas poae colonies isolated from contaminated packed red blood cell unit, Peoria, Illinois, USA, 2017, fluorescing under ultraviolet light (λ = 395 nm).
Figure 4Pseudomonas poae colonies isolated from contaminated packed red blood cell unit, Peoria, Illinois, USA, 2017, fluorescing under ultraviolet light (λ = 395 nm).
The annotated genome contained multiple copies of capB and cspA, genes for cold-shock domain proteins that enable efficient translation and long-term cold adaptation in Antarctic pseudomonads (Table 5) (17). Correlating this genomic signature with phenotypic data, we conducted a temperature-dependent viability experiment that confirmed growth at 4°C and 25°C (Figure 3) and no growth at 37°C; >99.9% of bacteria died within 5 days of incubation at 37°C. In addition, the annotated genome included evidence of versatile iron-acquisition capacities, including 2 siderophore systems and extracellular heme scavenging (Table 5) (18,19). Fluorescent siderophores are responsible for the fluorescence that gives the fluorescens group its name. Our isolate did demonstrate fluorescence under ultraviolet light, consistent with siderophore production (Figure 4).

Discussion

WGS analysis identified the organism within the red blood cell unit from this case as Ppoae, a cold-adapted fluorescens pseudomonad first discovered in the grass phyllosphere in 2003 and since found around the world, including the cold deserts of the Himalayas (20,21). Previous studies of this organism have focused on its potential to promote plant growth through phosphate mobilization, its production of plant-protective antifungal metabolites (22,23), and its ability to remediate contaminated ecosystems through hydrocarbon degradation (24). A Medline search yielded no reports of Ppoae as a human pathogen. Considering how poorly this isolate tolerated body temperature (37°C), the lack of clinical cases might reflect a genuinely low virulence in humans.
The pathogenicity of this organism seems specific to the ecology of red blood cell storage and transfusion. On both a genomic and phenotypic level, we found evidence of cold tolerance that particularly suited Ppoae to not just surviving but thriving in long-term refrigeration in a red blood cell unit. Because the organism grew at 25°C, any length of improper red blood cell storage at room temperature could have provided additional opportunity for growth. The versatile iron acquisition capacities suggested by genome annotation indicate the potential for Ppoae to exploit iron within the red blood cell unit environment (25). Although we cannot specify where the opportunity for colonization arose, Pseudomonas spp. have been traced to environmental sources, including contaminated water baths and cooling cloths in septic episodes involving blood products (26,27). Pseudomonas spp. are also common reagent contaminants detected in sequencing-based studies (28), suggesting that donor skin and the environment are not the only possible sources of contamination.
Once Ppoae was introduced into the patient, its survival was likely not required for virulence. Given a sufficiently large inoculum, the endotoxin and other antigens from both live and dead organisms that accumulated during the unit’s storage could have provided enough of an immunogenic stimulus within the bloodstream to trigger a massive dysregulated immune response, irrespective of the ability of the organism to establish a sustained infection at 37°C (29). Indeed, endotoxin is sufficient to activate multiple innate immune pathways that contribute to the hemodynamic, metabolic, and coagulation defects driving death due to sepsis (30,31). In the case we describe, how the history of methicillin-resistant Saureus sepsis <1 week before the infection affected the patient’s risk for death is unclear; systemic weakening or modification of the subsequent immune response could have been contributing factors that affected the patient’s outcome. Studies of sepsis in animals with previous endotoxin exposure suggest diverging effects of this priming on the basis of the dose (32,33); in vitro, cell wall components of gram-positive bacteria (e.g., lipoteichoic acid) appear to potentiate cytokine responses at low doses of endotoxin and suppress them at high doses (34).
National Healthcare Safety Network criteria for a definite TTI are predicated on pathogen identification, which requires not only a Gram stain, as done in this case, but also a positive blood culture and subsequent isolation on solid media (8). Although standard laboratory testing alone did not meet National Healthcare Safety Network criteria for a definite TTI in this case, we believe the presence of the Ppoaeisolate in the transfused blood product was the cause of death for this patient. The patient’s clinical deterioration from hemodynamic stability to death by cardiovascular collapse progressed during the 10 hours immediately after transfusion, and WGS provided postmortem evidence of Ppoae in the red blood cell unit. Although Ppoae is ubiquitous in soil, this patient had no other plausible systemic exposures to this otherwise nonpathogenic organism. In addition, the patient becoming infected with Ppoae before transfusion was overwhelmingly unlikely; she had received a 6-day course of empiric piperacillin/tazobactam covering gram-negative organisms for her periprosthetic infection within 48 hours of the transfusion, and her negative blood cultures before transfusion make any preexisting bloodstream infection with any Pseudomonas spp. highly improbable. Given that we believe the organism caused the patient’s death without establishing infection, the more appropriate term in this case would be septic transfusion reaction rather than TTI.
Because of the rapid death of this patient, a patient-derived blood sample was not accessible for next-generation sequencing and endotoxin testing, limiting our study. Because Ppoae is a ubiquitous plant- and soil-associated organism, we also cannot definitively exclude that the isolate we sequenced was not a contaminant from postmortem handling of the red blood cell unit. However, the absence of these gram-negative organisms (which were visible in blood smears acquired from the blood bag within 5 hours after transfusion) in the standard 37°C blood culture is consistent with the temperature intolerance observed for the gram-negative isolate later recovered from the red blood cell unit. Moreover, the growth of this isolate at 4°C coupled with the observation that most fatal bacterial TTIs are caused by cold-tolerant gram-negative organisms (e.g., Serratia spp., Yersinia enterocolitica) suggests that the isolate we recovered originated from the refrigerated red blood cell unit (Table 1) (35).
Our case expands the literature on microbially mediated deaths from red blood cell transfusions and represents an extraordinary human fatality from Ppoae. This episode draws attention to the limitations of standard blood culture procedures to fulfill National Healthcare Safety Network TTI criteria, which, for all practical purposes, require that organisms be incubated under conditions that much more resemble the human body than the cold storage environment selecting for the contaminating organisms. Ppoae is a prime example of an organism that could, by virtue of the very temperature-dependent growth that enables its survival in refrigerated red blood cell units, elude detection in a transfusion reaction investigation. Until guidelines expand to include cultures for bacteria that grow at storage temperature, the number of apparently culture-negative adverse transfusion reactions that are caused by similar organisms will remain unknown. Finally, our case demonstrates the potential for next-generation sequencing to detect, identify, and characterize organisms directly from contaminated blood products.
Dr. Woodring is a graduate of the University of Illinois College of Medicine in Peoria, Illinois. Her primary research interests include clinical microbiology and incorporating next-generation sequencing into infectious disease diagnostics.
Dr. Farrell is Chair of Infection Control for OSF Saint Francis Medical Center, director of the Serology and Microbiology Laboratories in the OSF System Laboratory, and professor of clinical medicine in the Division of Infectious Diseases for the University of Illinois College of Medicine. His research interests include molecular diagnostics with a focus on detection of bacterial pathogens in culture-negative tissues and body fluids.

Acknowledgment

The authors thank the clinical laboratory scientists in the blood bank and microbiology sections of the OSF System Laboratory for their assistance, especially Angie McKeever and Valerie Gosack. We also thank Jim Carlson for photographing the isolate and Trisha Stetzler for her excellent medical care.

References

  1. Centers for Disease Control and Prevention. Blood safety. Diseases and organisms. 2017 [cited 2018 Nov 25]. https://www.cdc.gov/bloodsafety/bbp/diseases-organisms.html
  2. Haass  KASapiano  MRPSavinkina  AKuehnert  MJBasavaraju  SVTransfusion-Transmitted Infections Reported to the National Healthcare Safety Network Hemovigilance Module. Transfus Med Rev2019;33:8491DOIExternal LinkPubMedExternal Link
  3. Kuehnert  MBasavaraju  SV. Transfusion-associated infections. In: Bennett JE, Dolin R, Blaser MJ, editors. Mandell, Douglas, and Bennett’s principles and practice of infectious diseases. 8th ed. Philadelphia: Saunders; 2015. p. 3351–60.
  4. Silverglied  AJ. Pathogen inactivation of blood products. 2018 May 23 [cited 2018 Nov 25]. https://www.uptodate.com/contents/pathogen-inactivation-of-blood-productsExternal Link
  5. D’Alessandro  AD’Amici  GMVaglio  SZolla  LTime-course investigation of SAGM-stored leukocyte-filtered red bood cell concentrates: from metabolism to proteomics. Haematologica2012;97:10715DOIExternal LinkPubMedExternal Link
  6. D’Alessandro  AKriebardis  AGRinalducci  SAntonelou  MHHansen  KCPapassideri  ISet al. An update on red blood cell storage lesions, as gleaned through biochemistry and omics technologies. Transfusion2015;55:20519DOIExternal LinkPubMedExternal Link
  7. Centers for Disease Control and Prevention. National Healthcare Safety Network biovigilance component hemovigilance module surveillance protocol. 2018 Apr [cited 2018 Nov 25]. https://www.cdc.gov/nhsn/pdfs/biovigilance/bv-hv-protocol-current.pdf
  8. De Coster  WD’Hert  SSchultz  DTCruts  MVan Broeckhoven  CNanoPack: visualizing and processing long-read sequencing data.Bioinformatics2018;34:26669DOIExternal LinkPubMedExternal Link
  9. Koren  SWalenz  BPBerlin  KMiller  JRBergman  NHPhillippy  AMCanu: scalable and accurate long-read assembly via adaptive k-mer weighting and repeat separation. Genome Res2017;27:72236DOIExternal LinkPubMedExternal Link
  10. Wick  RRSchultz  MBZobel  JHolt  KEBandage: interactive visualization of de novo genome assemblies. Bioinformatics2015;31:33502DOIExternal LinkPubMedExternal Link
  11. Loman  NJQuick  JSimpson  JTA complete bacterial genome assembled de novo using only nanopore sequencing data. Nat Methods2015;12:7335DOIExternal LinkPubMedExternal Link
  12. Seemann  TProkka: rapid prokaryotic genome annotation. Bioinformatics2014;30:20689DOIExternal LinkPubMedExternal Link
  13. Mulet  MLalucat  JGarcía-Valdés  EDNA sequence-based analysis of the Pseudomonas species. Environ Microbiol2010;12:151330.PubMedExternal Link
  14. Kearse  MMoir  RWilson  AStones-Havas  SCheung  MSturrock  Set al. Geneious Basic: an integrated and extendable desktop software platform for the organization and analysis of sequence data. Bioinformatics2012;28:16479DOIExternal LinkPubMedExternal Link
  15. Bodilis  JNsigue-Meilo  SBesaury  LQuillet  LVariable copy number, intra-genomic heterogeneities and lateral transfers of the 16S rRNA gene in Pseudomonas. PLoS One2012;7:e35647DOIExternal LinkPubMedExternal Link
  16. Panicker  GMojib  NNakatsuji  TAislabie  JBej  AKOccurrence and distribution of capB in Antarctic microorganisms and study of its structure and regulation in the Antarctic biodegradative Pseudomonas sp. 30/3. Extremophiles2010;14:17183DOIExternal LinkPubMedExternal Link
  17. Cornelis  PIron uptake and metabolism in pseudomonads. Appl Microbiol Biotechnol2010;86:163745DOIExternal LinkPubMedExternal Link
  18. Blin  KWolf  TChevrette  MGLu  XSchwalen  CJKautsar  SAet al. antiSMASH 4.0-improvements in chemistry prediction and gene cluster boundary identification. Nucleic Acids Res2017;45(W1):W3641DOIExternal LinkPubMedExternal Link
  19. Behrendt  UUlrich  ASchumann  PFluorescent pseudomonads associated with the phyllosphere of grasses; Pseudomonas trivialissp. nov., Pseudomonas poae sp. nov. and Pseudomonas congelans sp. nov. Int J Syst Evol Microbiol2003;53:14619DOIExternal LinkPubMedExternal Link
  20. Vyas  PRahi  PGulati  AStress tolerance and genetic variability of phosphate-solubilizing fluorescent Pseudomonas from the cold deserts of the trans-Himalayas. Microb Ecol2009;58:42534DOIExternal LinkPubMedExternal Link
  21. Gulati  ARahi  PVyas  PCharacterization of phosphate-solubilizing fluorescent pseudomonads from the rhizosphere of seabuckthorn growing in the cold deserts of Himalayas. Curr Microbiol2008;56:739DOIExternal LinkPubMedExternal Link
  22. Cho  KMHong  SYLee  SMKim  YHKahng  GGLim  YPet al. Endophytic bacterial communities in ginseng and their antifungal activity against pathogens. Microb Ecol2007;54:34151DOIExternal LinkPubMedExternal Link
  23. Khan  AHAnees  MArshad  MMuhammad  YSIqbal  MYousaf  SEffects of illuminance and nutrients on bacterial photo-physiology of hydrocarbon degradation. Sci Total Environ2016;557-558:70511DOIExternal LinkPubMedExternal Link
  24. Collard  KWhite  DCopplestone  AThe influence of storage age on iron status, oxidative stress and antioxidant protection in paediatric packed cell units. Blood Transfus2014;12:2109.PubMedExternal Link
  25. Brecher  MEHay  SNBacterial contamination of blood components. Clin Microbiol Rev2005;18:195204DOIExternal LinkPubMedExternal Link
  26. Chaffin  DJKuehnert  MJPseudomonas fluorescens–related septic transfusion reaction resulting from contaminated cold cloths.Transfusion2002;42:41S.
  27. de Goffau  MCLager  SSalter  SJWagner  JKronbichler  ACharnock-Jones  DSet al. Recognizing the reagent microbiome. Nat Microbiol2018;3:8513DOIExternal LinkPubMedExternal Link
  28. van der Poll  Tvan de Veerdonk  FLScicluna  BPNetea  MGThe immunopathology of sepsis and potential therapeutic targets. Nat Rev Immunol2017;17:40720DOIExternal LinkPubMedExternal Link
  29. Bryant  CESpring  DRGangloff  MGay  NJThe molecular basis of the host response to lipopolysaccharide. Nat Rev Microbiol2010;8:814DOIExternal LinkPubMedExternal Link
  30. Opal  SMThe host response to endotoxin, antilipopolysaccharide strategies, and the management of severe sepsis. Int J Med Microbiol2007;297:36577DOIExternal LinkPubMedExternal Link
  31. Chen  KGeng  SYuan  RDiao  NUpchurch  ZLi  LSuper-low dose endotoxin pre-conditioning exacerbates sepsis mortality.EBioMedicine2015;2:32433DOIExternal LinkPubMedExternal Link
  32. Wheeler  DSLahni  PMDenenberg  AGPoynter  SEWong  HRCook  JAet al. Induction of endotoxin tolerance enhances bacterial clearance and survival in murine polymicrobial sepsis. Shock2008;30:26773DOIExternal LinkPubMedExternal Link
  33. Kim  HJung  BJKim  JYChung  DKDifferential effects of low and high doses of lipoteichoic acid on lipopolysaccharide-induced interleukin-6 production. Inflamm Res2014;63:41928DOIExternal LinkPubMedExternal Link
  34. Roth  VRArduino  MJNobiletti  JHolt  SCCarson  LAWolf  CFet al. Transfusion-related sepsis due to Serratia liquefaciens in the United States. Transfusion2000;40:9315DOIExternal LinkPubMedExternal Link
Figures
Tables
Cite This Article

DOI: 10.3201/eid2508.181936
Original Publication Date: 7/10/2019

No hay comentarios:

Publicar un comentario