viernes, 25 de abril de 2014

Indoor Firing Ranges and Elevated Blood Lead Levels — United States, 2002–2013

full-text ►

Indoor Firing Ranges and Elevated Blood Lead Levels — United States, 2002–2013



MMWR Logo
 
MMWR Weekly
Vol. 63, No. 16
April 25, 2014
 
PDF of this issue


Indoor Firing Ranges and Elevated Blood Lead Levels — United States, 2002–2013

Weekly

April 25, 2014 / 63(16);347-351


Catherine Beaucham, MPH1, Elena Page, MD1, Walter A. Alarcon, MD1, Geoffrey M. Calvert, MD1, Mark Methner, PhD1, Todd M. Schoonover, PhD2 (Author affiliations at end of text)
Indoor firing ranges are a source of lead exposure and elevated blood lead levels (BLLs) among employees, their families, and customers, despite public health outreach efforts and comprehensive guidelines for controlling occupational lead exposure (1). There are approximately 16,000–18,000 indoor firing ranges in the United States, with tens of thousands of employees. Approximately 1 million law enforcement officers train on indoor ranges (1). To estimate how many adults had elevated BLLs (≥10 µg/dL) as a result of exposure to lead from shooting firearms, data on elevated BLLs from the Adult Blood Lead Epidemiology and Surveillance (ABLES) program managed by CDC's National Institute for Occupational Safety and Health (NIOSH) were examined by source of lead exposure. During 2002–2012, a total of 2,056 persons employed in the categories "police protection" and "other amusement and recreation industries (including firing ranges)" had elevated BLLs reported to ABLES; an additional 2,673 persons had non–work-related BLLs likely attributable to target shooting. To identify deficiencies at two indoor firing ranges linked to elevated BLLs, the Washington State Division of Occupational Safety and Health (WaDOSH) and NIOSH conducted investigations in 2012 and 2013, respectively. The WaDOSH investigation found a failure to conduct personal exposure and biologic monitoring for lead and also found dry sweeping of lead-containing dust. The NIOSH investigation found serious deficiencies in ventilation, housekeeping, and medical surveillance. Public health officials and clinicians should ask about occupations and hobbies that might involve lead when evaluating findings of elevated BLLs. Interventions for reducing lead exposure in firing ranges include using lead-free bullets, improving ventilation, and using wet mopping or high-efficiency particulate air (HEPA) vacuuming to clean (1).
ABLES Data, 2002–2012
In 2012, 41 states participated in ABLES, receiving notification from laboratories and physicians of elevated BLLs in persons aged ≥16 years through reporting mandated by state laws (2). Only the highest BLL was included if more than one was collected within a single year from an individual. Workers in the categories "police protection" or "other amusement and recreation industries" (OARI), which includes firing ranges, were considered to have occupational lead exposures.
During 2002–2012, a total of 2,056 persons in the two industry categories had BLLs ≥10 µg/dL; 785 had BLLs ≥25 µg/dL, and 1,271 had BLLs of 10–24µg/dL. Of the 2,056, a total of 631 (31%) were employed in police protection, and 1,425 (69%) were employed in OARI (Table 1). During 2002–2012, non–work-related target shooting was the likely exposure for an additional 2,673 persons with elevated BLLs (1,290 with BLLs ≥25 µg/dL and 1,388 with BLLs of 10–24 µg/dL).
WaDOSH Investigation, 2012
In 2010, the Washington state ABLES program requested an inspection by WaDOSH of an indoor firing range after seven employees were found to have elevated BLLs. WaDOSH issued citations for violations of seven sections of their workplace lead standard, which is identical to the federal Occupational Safety and Health Administration (OSHA) standard.
In October 2012, the state ABLES program received reports of BLLs of 40 µg/dL and 48 µg/dL in two employees of the same range. Interviews revealed ongoing renovation at the range beginning in September 2012, including replacing the sand berm bullet trap with a steel bullet trap, replacing the ventilation system, and adding a second floor. Review of records revealed that from 2010 until the onset of renovation, 19 range employees had BLLs of 12–50 µg/dL. Following initial ABLES interviews, a compliance inspection from WaDOSH was conducted.
In the 2012 inspection, WaDOSH noted the ventilation system was inoperable and temporarily replaced by two roof fans that exhausted unfiltered air outside. Multiple citations were issued for violations of the workplace lead standard, including failure to conduct personal exposure and biologicmonitoring for lead, dry sweeping of lead-containing dust, and lack of respirator medical clearance and fit testing.
During renovation of the firing range, 117 construction workers and 42 range employees were present. A total of 98 of these persons received BLL testing, and 46 (47%) had elevated BLLs, including 26 construction workers (BLLs of 10–153 µg/dL) and 20 range employees (BLLs of 14–58 µg/dL). The BLL of 153 µg/dL was recorded approximately 10 weeks after the construction worker began dismantling the frame of the sand berm and installing the steel bullet trap. Interviews with nine construction workers and six range employees with BLLs ≥40 µg/dL documented inadequate knowledge regarding the hazards of workplace and "take-home" lead exposures (e.g., lead transferred to family members via clothing or automobile interiors). As a result of this investigation, WaDOSH initiated standardized inspections of all firing ranges in the state, including exposure monitoring and lead safety training for firing range employees.
The state ABLES program advised employees to have family members tested; three children and two adult family members of four construction workers had BLLs ≥5 µg/dL. Positive tests for surface lead contamination in homes and vehicles of several workers required lead abatement from hard surfaces, carpeting, and upholstery. A recreational shooter at the range reported a BLL of 12.9 µg/dL to public health authorities.
NIOSH Investigation, 2013
In December 2013, at the request of employees, NIOSH investigators evaluated lead exposure at an indoor firing range and firearms retailer in California. Investigators reviewed medical and exposure records, interviewed five of the six employees, collected air and surface wipe samples for lead, and evaluated the ventilation systems for the range and showroom. Employees spent most of their work day on the sales floor or in the office, entering the range generally to assist shooters experiencing difficulty. Employees cleaned the range daily using a floor squeegee for spent bullet casings and a HEPA-filtered vacuum cleaner on carpeted areas. They replaced filters in the range exhaust ventilation system and scraped and oiled the steel bullet trap weekly.
Numerous deficiencies were found (Table 2). Six full-shift personal air samples from monitors worn by showroom employees had lead concentrations of 5.5–19 µg/m3, within the current OSHA occupational exposure limit of 50 µg/m3. Two task-based air samples for lead had high short-term (<1 hour) concentrations of 54 µg/m3 (for nightly range maintenance) and 64 µg/m(for weekly range cleaning). Lead was detected on all surfaces tested. Employee BLL testing had been conducted for the first time immediately before the NIOSH evaluation, and BLLs ranged from 19.9 µg/dL to 40.7 µg/dL. No employees had undergone other medical surveillance as required by the California Division of Occupational Safety and Health and OSHA (3). Recommendations were made to minimize employee and customer exposure to lead, and the county public health officer was notified regarding risks to customers from airborne and surface lead exposure. Employees were advised to send family members for BLL testing because of the potential for take-home lead exposures.

Discussion

The ABLES data and the two investigations summarized in this report document serious lead exposure from indoor firing ranges (4). Employers in general industry are required by law to follow the OSHA lead standard established in 1978 (3,5). OSHA considers the permissible airborne lead exposure limit of 50 µg/m3 and allowable BLLs to be outdated (5,6).* The National Toxicology Program recently released a monograph on the potential health effects of low-level lead exposure to adults (7) (Table 3).
In 2013, the California Department of Public Health recommended that the California Division of Occupational Safety and Health lower the permissible exposure limit for lead in air to 0.5–2.1 µg/m3 to keep BLLs below the range of 5–10 µg/dL (8). Guidelines for management of lead exposed employees (9) are endorsed by the California Department of Public Health, the Council of State and Territorial Epidemiologists, and the American College of Occupational and Environmental Medicine, and recommended by NIOSH (1). Importantly, these guidelines are not based on airborne lead levels, but on monitoring BLLs, which can reflect exposure through any route. BLLs should be kept below 10 µg/dL for all adults, and below 5 µg/dL for children and pregnant women (9).
The findings in this report also suggest that firing range customers and family members of firing range employees, in addition to employees themselves, can be exposed to hazardous amounts of lead. There are an estimated 19 million active target shooters in the United States (10).
The findings in this report are subject to at least five limitations. First, employers might not provide BLL testing to all lead-exposed employees as required. Second, adults with non–work-related exposures are not likely to be tested, and BLLs of recreational shooters are not consistently available. Third, certain laboratories might not report BLL test results as required. Fourth, how many of the elevated BLLs were related to firing range exposures is not known. Because the OARI industry category includes industries other than firing ranges (e.g., miniature golf courses and billiard parlors), it is possible that some OARI workers with occupational BLL elevations were not employed in firing ranges. Finally, the two investigations did not determine the full extent of take-home exposures and other sources of lead exposure among firing range workers and customers.
The number of persons with elevated BLLs from firearms use during 2011–2012 highlights the need to increase prevention activities. Airborne and surface lead levels in firing ranges can be greatly reduced by using lead-free bullets, improving ventilation systems, using wet mopping or HEPA vacuuming instead of dry sweeping, and having a written protocol for range maintenance (1). Measures also should be taken to prevent take-homeexposure.

Acknowledgments

Steve Whittaker, Ryan Kellogg, Public Health — Seattle and King County; Venetia Runnion, Gina Colby, John Stebbins, Division of Occupational Safety and Health, Washington State Department of Labor and Industries; Rad Cunningham, Division of Environmental Public Health, Washington State Department of Health. Michael Kinzer, EIS officer, CDC. ABLES program coordinators, 41 states.
1Div of Surveillance, Hazard Evaluations, and Field Studies, National Institute for Occupational Safety and Health, CDC; 2Washington State ABLES Program, Washington State Department of Labor and Industries (Corresponding contributor: Catherine Beaucham, cbeaucham@cdc.gov, 513-841-4259)

References

  1. CDC. Preventing occupational exposure to lead and noise at indoor firing ranges. NIOSH alert 2009. Cincinnati, OH: US Department of Health and Human Services, CDC, National Institute for Occupational Safety and Health; 2009. Available at http://www.cdc.gov/niosh/docs/2009-136/pdfs/2009-136.pdf Adobe PDF file.
  2. CDC. Adult Blood Lead Epidemiology and Surveillance (ABLES). Cincinnati, OH: US Department of Health and Human Services, CDC, National Institute for Occupational Safety and Health; 2013. Available at http://www.cdc.gov/niosh/topics/ables/description.html.
  3. Occupational Safety and Health Administration. Lead standards: general industry (29 CFR 1910.1025) and construction industry (29 CFR 1926.62). Washington, DC: US Department of Labor, Occupational Safety and Health Administration; 1978. Available at https://www.osha.gov/sltc/leadExternal Web Site Icon.
  4. National Research Council of the National Academies. Report from the Committee on Potential Health Risks from Recurrent Lead Exposure of DOD Firing Range Personnel. Washington, DC: National Academies Press; 2013.
  5. Occupational Safety and Health Administration. Permissible exposure limits—annotated tables. Washington, DC: US Department of Labor, Occupational Safety Administration; 2014. Available at https://www.osha.gov/dsg/annotated-pels/index.htmlExternal Web Site Icon.
  6. Chen I. Overlooked: thousands of Americans exposed to dangerous levels of lead in their jobs. Scientific American, August 20, 2013. Available athttp://www.scientificamerican.com/article/overlooked-thousands-of-american-exposed-to-dangerous-levels-of-lead-in-their-jobs/?page=1External Web Site Icon.
  7. National Toxicology Program. Health effects of low-level lead evaluation. Research Triangle Park, NC: US Department of Health and Human Services, National Toxicology Program; 2013. Available at http://ntp.niehs.nih.gov/go/36443External Web Site Icon.
  8. Billingsley KJ. Letter of September 30, 2013, from K. J. Billingsley, California Department of Public Health, to Juliann Sum, Division of Occupational Safety and Health (Cal/OSHA), California Department of Industrial Relations. Re: Health-based permissible exposure limit for lead. Available athttp://www.cdph.ca.gov/programs/olppp/documents/leadstdpelrec.pdf Adobe PDF fileExternal Web Site Icon.
  9. Kosnett MJ, Wedeen, RP, Rothenberg SJ, et al. Recommendations for medical management of adult lead exposure. Environ Health Perspect 2007;115:463–71.
  10. National Shooting Sports Foundation. The shooting sports, 2014. Newtown, CT: National Shooting Sports Foundation; 2014. Available athttp://www.nssf.org/shooting/sportsExternal Web Site Icon.

No hay comentarios: