EID Journal Home > Volume 17, Number 6–June 2011
Volume 17, Number 6–June 2011
Letter
Easy Diagnosis of Invasive Pneumococcal Disease
Laura Selva, Xavier Krauel, Roman Pallares, and Carmen Muñoz-Almagro
Author affiliations: University Hospital Sant Joan de Déu, Barcelona, Spain (L. Selva, X. Krauel, C. Muñoz-Almagro); Saint John of God Hospital, Lunsar, Sierra Leone (X. Krauel); Bellvitge Hospital, Barcelona (R. Pallares); and University of Barcelona, Barcelona (R. Pallares)
Suggested citation for this article
To the Editor: Invasive pneumococcal disease (IPD) causes many cases of severe disease and death among children <5 years of age, mostly in developing countries (1,2). Before conjugate vaccines can be introduced in developing countries, information about disease epidemiology is urgently needed. The lack of laboratories equipped to perform pneumococcal serotyping leads to the need to send isolates to reference laboratories. Good sample preservation is necessary to prevent samples from arriving at the laboratory in poor condition. We evaluated the usefulness of multiplex real-time PCR from strains and blood samples kept at room temperature on dried blood spot (DBS) filter paper for detecting and serotyping Streptococcus pneumoniae. DBS screening is a reliable method that requires only a small amount of blood; it is used for the diagnosis of several human diseases (3,4).
To validate the technique, we selected 15 pneumococcus clinical isolates representing 15 serotypes (1, 5, 19A, 19F, 14, 3, 7F, 4, 6A, 6B, 8, 9N, 18C, 23A, 23F) obtained during 2009 from patients at Hospital Sant Joan de Déu, in Barcelona. These isolates, used as controls, had been serotyped by quellung reaction at the Instituto de Salud Carlos III, Majadahonda-Madrid, Spain. These strains were cultured overnight at 35°C in 5% carbon dioxide on Columbia agar plates with 5% sheep blood (bioMérieux SA, Marcy l'Etoile, France). A suspension of each strain was adjusted to match a 0.5 McFarland standard (equivalent to 108 colony-forming units (CFU)/mL). Stock solutions of pneumococcus culture for each previously identified serotype were injected into blood previously extracted from 2 healthy volunteers. Serial dilutions of 100,000 CFU/mL to 1,000 CFU/mL (1,000 to 10 CFU equivalents/PCR) were performed. A total of 100 μL of blood was applied to DBS filter paper, and another 100 μL was used for DNA extraction from fresh blood. All DBS samples were air dried for 1 week. The procedure was also performed on negative control blood samples.
DNA was extracted from DBS and fresh blood samples by using the NucliSense easyMAG automated extraction platform (bioMérieux, Boxtel, the Netherlands) according to the manufacturer's instructions. DNA detection of the pneumolysin (ply) gene by real-time PCR was performed according to a published assay (5). In addition, we performed a multiplex real-time PCR for molecular serotype detection of serotypes 1, 3, 5, 4, 6A, 6B, 7FA, 8, 9VANL, 14, 15BC, 18CB, 19A, 19FBC, 23F, 23A and the conserved capsular gene wzg as described by Tarrago et al. (6). DNA extracts were amplified with the Applied Biosystems 7300 Real-time PCR System (Applied Biosystems, Foster City, CA, USA). Negative results were defined as those with cycle threshold >40.
To evaluate the reliability obtained with this in vivo approach, we performed identification and serotyping of S. pneumoniae in 25 DBS samples from 25 children at Saint John of God Hospital in Mabesseneh-Lunsar, Sierra Leone. This hospital does not perform blood cultures. IPD was confirmed when DNA of a pneumolysin (ply) gene and an additional capsular gene of S. pneumoniae were detected by multiplex real-time PCR of DBS samples.
Detection of ply, wzg, and the specific gene for molecular serotype showed that both fresh blood and DBS samples yielded correctly positive results from the 10-fold serial dilutions analyzed (Table). With respect to the 25 (11 female and 14 male) patients from Sierra Leone who had suspected IPD, the median age was 25.71 months (range 15 days to 96 months); all had a diagnosis of fever without apparent source, and 16 also had malaria. Of these 25 children, DBS samples from 15 (60%) yielded a positive result for the ply and wzg genes, so they were considered confirmed episodes of IPD. A serotype included in 13-valent conjugate vaccine was detected in 6 (40%) of 15 positive samples: serotypes 3, 7FA, 19A, 6A, 6B, and 9VNL (1 sample each). In the remaining 9 samples, the results for ply gene and wzg gene were positive, but none of the 24 tested serotypes was detected.
This preliminary study enabled us to demonstrate that DBS screening is a reliable and easy method for diagnosing IPD and also for epidemiologic surveillance of the more frequent serotypes. The main limitation of our study is the small number of DBS samples sent from Saint John of God Hospital in Sierra Leone.
In conclusion, the DBS technique enables reproducible transport of samples for identification and serotyping of S. pneumoniae by multiplex PCR. The use of DBS on filter paper is an attractive alternative method for storing samples at room temperature and easily transporting them. Additional studies, including evaluation of the relative sensitivity of this method compared to direct culture, are necessary.
Acknowledgments
We thank members of the Sponsor the Treatment of a Child in Sierra Leone Foundation for taking care of patients and collecting samples for serotyping.
This study was supported by a grant from the Caja Navarra Foundation.
full-text:
Diagnosis of Invasive Pneumococcal Disease | CDC EID
Suggested Citation for this Article
Selva L, Krauel X, Pallares R, Muñoz-Almagro C. Easy diagnosis of invasive pneumococcal disease [letter]. Emerg Infect Dis [serial on the Internet]. 2011 Jun [date cited]. http://www.cdc.gov/EID/content/17/6/1125.htm
DOI: 10.3201/eid1706.100997
Comments to the Authors
Please use the form below to submit correspondence to the authors or contact them at the following address:
Carmen Muñoz-Almagro, Molecular Microbiology Department, University Hospital Sant Joan de Déu, P° Sant Joan de Déu, nº 2, 08950 Esplugues, Barcelona, Spain; email: cma@hsjdbcn.org
No hay comentarios:
Publicar un comentario